含Cr钢筋在水泥萃取液中的电化学腐蚀行为
周成1, 谭何灵1, 刘明2, 程学群2, 李晓刚2
1.北京科技大学材料科学与工程学院,北京100083;2.北京科技大学腐蚀与防护中心,北京100083
摘要:
利用极化曲线和交流阻抗谱研究比较了基材HRB400及添加不同Cr含量的3种钢筋在氯离子浓度不同的水泥萃取液中的腐蚀行为;利用Mott Schottky理论研究了4种钢筋钝化膜的半导体特性.结果表明:在同一腐蚀溶液中,随着钢筋中Cr含量的增加,钢筋腐蚀电流密度减小、钝化区间和极化电阻增大、钝化膜稳定性增强,钢筋耐腐蚀性能提高;随着溶液中氯离子浓度增大,钢筋腐蚀电流密度增大、钝化区间和极化电阻减小、载流子密度增大,钢筋耐腐蚀性能降低;Cr合金化的钢筋具有相对较好的耐蚀性.
关键词:  钢筋  水泥萃取液  极化曲线  电化学阻抗谱
DOI:103969/j.issn1007 9629201604007
分类号:
基金项目:国家重点基础研究发展计划(973计划)项目(2014CB643300);国家科技基础条件平台建设项目
Electrochemical Corrosion Behavior of Cr Modified Steel Rebars in Cement Extract Solution
ZHOU Cheng1, TAN Heling1, LIU Ming2, CHENG Xuequn2, LI Xiaogang2
1.School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, China;2.Corrosion and Protection Center, University of Science and Technology Beijing, Beijing 100083, China
Abstract:
Electrochemical corrosion behavior of HRB400 and three Cr modified steel rebars in cement extract solution with different chloride concentrations were estimated by potentiodynamic polarization curves and electrochemical impedance spectroscopy(EIS); semiconductor properties of passivation film of the four steel rebars were studied by Mott Schottky(M S) theory. The results show that with the increasing of Cr in the steel rebar, the corrosion current density decreases, passivation interval and polarization resistance increase, and the passivation film stability is enhanced, which indicates that the corrosion resistance of steel rebar is improved. In addition, increase of chloride concentration in cement extract solution leads to increase of the corrosion current density, decrease of the passivation interval and polarization resistance, and significant increase of the carrier density, while the corrosion resistance of steel rebar is decreased. Cr modified steel rebars have higher corrosion resistance than HRB400.
Key words:  steel rebar  cement extract solution  polarization curve  electrochemical impedance spectroscopy(EIS)