2 060 MPa级高强钢丝高温力学性能及破断模式
作者:
作者单位:

1.三峡大学 防灾减灾湖北省重点实验室(三峡大学),湖北 宜昌 443002;2.西南交通大学 土木工程学院,四川 成都 610031;3.佛山科学技术学院 交通与土木建筑学院,广东 佛山 528225

作者简介:

陈 巍(1991—),男,湖北随州人,三峡大学讲师,硕士生导师,博士. E-mail: 782851112@qq.com

通讯作者:

齐东春(1978—),男,湖北宜昌人,三峡大学副教授,硕士生导师,博士. E-mail: qidongchun@163.com

中图分类号:

U444

基金项目:

国家自然科学基金资助项目(51178396);防灾减灾湖北省重点实验室(三峡大学)开放基金资助项目(2023KJZ21);广东省基础与应用基础研究基金资助项目(2022A1515110289)


Mechanical Properties and Fracture Mode of 2 060 MPa Grade High-Strength Steel Wire at High-Temperature
Author:
Affiliation:

1.Hubei Key Laboratory of Disaster Prevention and Mitigation (China Three Gorges University), China Three Gorges University, Yichang 443002, China;2.School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, China;3.School of Transportation, Civil Engineering & Architecture, Foshan University, Foshan 528225, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    采用非接触式光学应变测试系统,跟踪测试了2 060 MPa级高强钢丝试件在20~900 ℃下的全过程应力-应变曲线,建立了高温钢丝各力学性能指标的高温函数模型,得到其高温破断参数.结果表明:高温下高强钢丝试件的各力学性能指标均有不同程度折损.当温度低于200 ℃时,试件的力学性能指标折损率不超过10%,破断模式为脆性破坏;当温度超过200 ℃后,试件的各力学性能指标折损率显著增大,破断模式逐渐由脆性破坏转变为塑性破坏.

    Abstract:

    The non-contact optical strain testing system was used to track and test the stress-strain curves of 2 060 MPa grade high-strength steel wire specimens throughout the entire process at 20-900 ℃. The mechanical performance index at high-temperature was determined, and the high-temperature fracture parameters of high-strength steel wire were obtained. The results indicate that the mechanical properties of high-strength steel wire specimens suffer various degrees of impairment at high-temperature. When the temperature does not exceed 200 ℃, the degradation of each mechanical property index of specimen shall not exceed 10%, and the fracture mode is brittle failure. After the temperature exceeds 200 ℃, the degradation of each mechanical property index of specimen significantly increases, and the fracture mode gradually changes from brittle failure to plastic failure.