Abstract:The condensate solution stuck to the inner wall of natural draft cooling tower with flue gas injection contains large amount of SO2-4, NO-3 and H+, and it could erode the inner wall concrete. Therefore, the durability of ordinary concrete(NC30), high performance concrete(HPC30 and HPC50) and ultra high performance concrete(UHPC) in the above environment under the actual operating temperature were studied through the indoor immersion experiments. The results show that the mass loss rate of NC30 reached the maximum, which is 76%, after 95days condensate solution immersion. But for UHPC the value is just 13%, and for HPC30 and HPC50, the value is 44% and 40%, respectively. The compressive strength of NC30, HPC30 and HPC50 increases first and then reduces with the increase of immersion time, and their strength loss rate is 403%,319% and 198%, respectively, after 95days immersion. The compressive strength of UHPC decreased with the increase of condensate solution immersion time, but its value is only 94% at the same time.