Abstract:Long term performance of skid resistance and conductivity of conductive ultra thin anti skidding wearing course(CUAWC) under freezing thawing cycles, soaking and repeated loading were evaluated by model mobile load simulator(MMLS3) and freezing thawing tests. Results show that the initial resistivity of the CUAWC is 418×10-3Ω·m, while the resistivity reduces to 415×10-3Ω·m after three freezing thawing cycles. The resistivity of the CUAWC increases by 50% after the coupling action of freezing thawing cycles and 1million cumulative load, and rises by 25% after 500 thousand cumulative soaking load. Moreover, the initial BPN value of the CUAWC is within 6567BPN, while BPN value decreases by 100% after the coupling action of freezing thawing cycles and 1million cumulative load, and reduces by 60% after 500 thousand cumulative soaking load. The test results indicate that CUAWC has good long term performance of skid resistance and conductivity. In addition, the heating power of CUAWC with 2m electrode gap can reach 4277W/m2 at 36V, which meets the need for melting ice and snow on road surface.