Abstract:Ultrasonic P-wave transducer and ultrasonic single side method were used to determine concrete dynamic elastic modulus.A new method for calculating R-wave velocity is proposed based on peaks of the received wave signal.The method can reduce the influence of the P-wave reflected by the bottom or external boundaries.Comparing the concrete elastic modulus obtained by ultrasonic method with tapping method,the results are consistent.